SRL Engine

Systematic Review Software: PRISMA 2020, Dual Screening, Kappa and Word Export

Author: Engin Kurşun · ORCID 0000-0002-5649-8595

Published:

SRL Engine's systematic review module is systematic review software that runs in your browser. It imports records from database export files and finds duplicates. It lets two or more people screen the same records without seeing each other's decisions, and it measures their agreement with Cohen's kappa. It fills in the PRISMA 2020 flow diagram from your project records. It keeps quality appraisal (RoB 2, ROBINS-I, MMAT, JBI, Newcastle-Ottawa) and certainty of evidence (GRADE, GRADE-CERQual) in the same project, and exports APA 7 tables to Word. There is nothing to install.

It is built for researchers writing a thesis, a journal article or a review aimed at Q1, SSCI or SCIE journals. AI helps with screening, data extraction, quality appraisal and report writing, and those steps cost credits. You can also do every step by hand, without AI.

How a review project runs

  1. Collect records in Reference Management. Upload the files you exported from databases and remove duplicates.
  2. Screen titles and abstracts. Write your inclusion and exclusion criteria and make your decisions. Send the included records to a systematic review project with "Send to module".
  3. Planning: Add at least one research question. Questions are used in screening, extraction and the report.
  4. Screening: In full-text screening, include or exclude each study.
  5. Data extraction: Collect data from each study into fields you define.
  6. Quality appraisal: Pick the tool that fits the study design.
  7. Analysis and synthesis: Turn extracted data into categories, synthesise the findings and rate the certainty of evidence.
  8. Reporting: Download the PRISMA diagram, the methods and results sections, and the tables as Word files.

A bar at the top of the project shows which step you are on and what comes next. You can invite team members and give them a role (administrator, reviewer or observer).

Importing records and removing duplicates

  • Supported files: RIS (.ris, .nbib, .txt), BibTeX (.bib), CSV and Excel (.csv, .xlsx). For PubMed you can also paste a list of PMIDs.
  • Databases: The importer reads export files from Web of Science, Scopus, PubMed, ERIC, IEEE Xplore, EBSCOhost, ClinicalTrials.gov, the WHO ICTRP and similar sources. The import screen explains how to download the file from the database you select. For example, it reminds you that Scopus includes reference lists only in the CSV export.
  • Source counts: You choose the source database for each import. The record count per database goes into the Identification part of the PRISMA diagram. Records from trial registers such as ClinicalTrials.gov are counted on a separate Registers line.
  • Finding duplicates: Records with the same DOI or PMID are duplicates. For records without an identifier, title similarity, first and last author, year and journal name are scored together. Two records with different DOIs are never merged, however similar their titles. This keeps separate papers such as "Part 1" and "Part 2" from being deleted.
  • Which copy stays: You merge pairs one by one or in bulk. The copy that stays is chosen in the order Web of Science, Scopus, PubMed, then other sources. The number of removed copies goes into the "duplicate records removed" box in PRISMA.
  • Full texts: For records with a DOI, open-access PDFs can be searched for in Unpaywall, OpenAlex, Semantic Scholar and Europe PMC. You upload the PDFs that cannot be found.

PRISMA 2020 flow diagram

PRISMA 2020 provides a 27-item checklist and flow diagram templates for reporting systematic reviews (Page et al., 2021). Journals that endorse PRISMA may require a completed checklist and flow diagram as a condition of submission (PRISMA, n.d.-a).

  • Counts fill in automatically: Records per database and register, duplicates removed, records screened, records excluded at title and abstract, reports sought, reports not retrieved, reports assessed, reports excluded with reasons, and studies included are all calculated from your project records.
  • Each excluded study has one reason: The reason is picked from the project's list of exclusion criteria, not typed freely. That way the reasons add up to the number of excluded studies. At full-text stage, the "Full text not retrieved" option is counted as "reports not retrieved" in the diagram.
  • Other methods column: Records that did not come from a database search (added by hand, fetched by DOI, or marked with a route such as "citation searching") are counted separately in the right-hand column of the template, "identification of studies via other methods". The official PRISMA site offers this two-column template for new reviews (PRISMA, n.d.-b).
  • Manual edits: You can edit the counts and labels in the diagram. An edited diagram is tagged "Manually Edited".
  • Export: The diagram downloads in English as SVG, PNG or PDF. As a Word file it is a bordered table rather than an image, so you can change the numbers and text in each box in Word. The Word version follows the interface language, Turkish or English.

The PRISMA 2020 flow diagram guide explains each box and where its numbers come from.

Dual independent screening and kappa

The Cochrane Handbook asks for at least two people working independently to decide whether each study is eligible. Ideally, title and abstract screening is also done in duplicate, although one person may do this first pass. Two people working independently are essential for the final decision based on full texts (Lefebvre et al., 2025). A methodological review of 23 single-reviewer screenings found a median of 5% of relevant studies missed. The figure was 3% for experienced reviewers and 13% for less experienced ones (Waffenschmidt et al., 2019).

Independent coding in SRL Engine works like this:

  • Assignment: The project owner or admin assigns the same records to two or more coders. For quality appraisal and data extraction, the sample is drawn only from included studies.
  • Blinding: On the independent coding screen, each coder sees only the bibliographic details of the records assigned to them. The other coder's decision, reasoning and any AI flag are not shown there.
  • The workflow is untouched: The second coder's decision does not change a record's status; it only feeds the agreement measure.
  • Consensus: Disagreements are listed. The project owner or admin makes the consensus decision and can undo it. Consensus decisions are not counted in kappa, and the report states how many disagreements were resolved by consensus.
  • Measures: For screening decisions, raw (percent) agreement and Cohen's kappa (Cohen, 1960) are calculated. "Uncertain" decisions are left out of kappa and their number is reported. For quality items, ordinal scales such as RoB 2 and ROBINS-I use weighted kappa, and checklists such as JBI and MMAT use unweighted kappa. For fields extracted as text, percent agreement and kappa are reported together.
  • Interpretation and reporting: Kappa is interpreted with the Landis and Koch (1977) benchmarks. The screen gives a sentence ready for your report in the interface language, Turkish or English. The same results appear as a table in the Word report and as a separate sheet in Excel. No personal names appear in the report; coders are written as "Coder 1" and "Coder 2".

Example: why kappa can stay low when raw agreement is high

In the two examples below, two coders screened 200 records. The numbers were produced with SRL Engine's own calculation function. Kappa corrects observed agreement (p₀) for the agreement expected by chance (pₑ): κ = (p₀ − pₑ) / (1 − pₑ). In Example 1, κ = (0.92 − 0.731) / (1 − 0.731) = 0.70.

Example 1Example 2
Both include242
Coder 1 includes, Coder 2 excludes66
Coder 1 excludes, Coder 2 includes106
Both exclude160186
Raw agreement92%94%
Agreement expected by chance (pₑ)0.7310.923
Cohen's kappa0.70 (substantial)0.22 (fair)
PABAK0.840.88

Example 2 has higher raw agreement but a much lower kappa. Because both coders excluded most of the records, the agreement expected by chance rises to 0.92. Byrt et al. (1993) showed that kappa is affected by how common each category is and by bias between observers, and recommended reporting indicators of both alongside kappa. So when raw agreement is high but kappa is low, the program also reports the prevalence- and bias-adjusted kappa (PABAK). The sentence it produces for Example 2:

Coder 1 and Coder 2 independently coded 200 records; raw agreement 94%, Cohen's kappa = 0.22 (fair agreement). The low kappa despite high raw agreement is the kappa paradox caused by decisions concentrating in one category; the prevalence- and bias-adjusted kappa is PABAK = 0.88 (Byrt et al., 1993).

Example 1 needs no such warning, so its sentence ends with raw agreement and kappa. The inter-rater reliability guide walks through the kappa calculation step by step.

Quality appraisal

  • Tools: Cochrane RoB 2 (randomised trials, with a separate template for crossover trials), ROBINS-I (non-randomised studies of interventions), MMAT 2018, JBI checklists (RCTs, quasi-experimental, cohort, case-control, analytical cross-sectional, prevalence, qualitative, diagnostic test accuracy, case reports, case series, economic evaluations, text and opinion, systematic reviews), the Newcastle-Ottawa Scale, the 11 items of Dybå and Dingsøyr, and tools you define yourself.
  • RoB 2 and ROBINS-I work at domain level: RoB 2 was developed for randomised trials (Sterne et al., 2019). Each of its five domains is judged as "low risk of bias", "some concerns" or "high risk of bias" (Higgins et al., 2024). ROBINS-I is for non-randomised studies of interventions (Sterne et al., 2016). In SRL Engine you enter the judgement for each domain yourself. The signalling-question algorithm is not built in.
  • MMAT uses one category per study: MMAT 2018 has five core criteria for each of five study design categories: qualitative, randomised controlled, non-randomised, quantitative descriptive and mixed methods (Hong et al., 2018). Each study is appraised with the one category that fits its design.
  • Tool suggestions: The program recognises the study design from extracted data or from the title, abstract and full text, and suggests a suitable tool. This uses no AI and no credits.
  • AI help: You can have AI fill in quality items for one study or in bulk, then correct them. This costs credits.
  • Figures: A traffic-light plot (each study's judgement, domain by domain) and a summary bar chart are drawn. Figures download as SVG or as 300 or 600 dpi PNG and are also placed in the Word report. Text inside the figures is in English.

Data extraction, analysis and synthesis

  • Extraction fields: You define the fields (for example sample, country, intervention, outcome measure). Fields are stored as text; sorting values into categories happens in the Analysis step.
  • AI extraction: AI fills each field from the paper's text and attaches a quote from the paper to the value. The program checks whether the quote actually appears in the paper. If it does not, the value is not saved and stays "Not reported". You see the quote in the form and can correct the value. Extraction costs credits per study.
  • Scanned PDFs: A PDF made only of images has no text to read. You enter the data for those studies by hand.
  • Analysis: You carry extracted data over into analysis fields (for example design or region). You can have AI group differently spelled values in a field into shared categories, and undo it; this costs credits. Figures summarising study characteristics are drawn from these fields.
  • Synthesis: You synthesise findings thematically or narratively, and AI can draft the text if you want. The evidence gap map crosses research questions, or one category, with another category and shows the studies in each cell.
  • When meta-analysis is not possible: The SWiM reporting guideline sets out nine reporting items for reviews in which effect estimates are not combined by meta-analysis (Campbell et al., 2020). The Effect direction tab brings the studies' effect directions together in an effect direction plot and a harvest plot.
  • Certainty of findings: You rate each synthesis finding with GRADE or GRADE-CERQual. GRADE suggests a summary of findings (SoF) table for quantitative findings (Guyatt et al., 2011). GRADE-CERQual assesses confidence in qualitative findings through methodological limitations, coherence, adequacy of data and relevance, and suggests a Summary of Qualitative Findings (SoQF) table (Lewin et al., 2018). Both tables export to Word.

Reporting and Word export

  • One Word file: The report has Methods, Results and Appendices. Methods covers the search strategy, inclusion and exclusion criteria, PRISMA, the quality appraisal protocol and data extraction. Results covers descriptive findings, the findings for each research question, a quality summary and certainty of findings. Appendices hold the study characteristics, data extraction, quality and theme tables.
  • Format: Tables follow APA 7: Times New Roman, 12 point, horizontal rules only. Headings use APA 7 level 1 and level 2 styles.
  • Search strategy table: For each database it lists the field, limits, record count, date and the query itself. The query is printed exactly as entered.
  • Section text: Write the sections yourself, or have AI draft them and then edit. AI costs credits per section. The program does not write the introduction or discussion.
  • Language: The full report currently uses Turkish section headings. The four tables from "Download All (Word)" have English captions. The Word version of the PRISMA diagram follows the interface language, Turkish or English.
  • Excel: Screening results and inter-rater agreement also export to Excel. If you screened in another tool, you can upload those decisions in bulk with a three-column Excel file (title, decision, reason).

Reviews for Q1, SSCI and SCIE journals

  • What SSCI and SCIE are: The Science Citation Index Expanded (SCIE) and the Social Sciences Citation Index (SSCI) are two indexes in Clarivate's Web of Science Core Collection (Clarivate, 2026). According to Clarivate's product pages, SCIE covers about 9,400 actively publishing journals in 178 subject categories, and SSCI about 3,500 in 58 subject categories (Clarivate, n.d.-b, n.d.-c).
  • What Q1 means: Journal Citation Reports (JCR) compares a journal with others in its category by Journal Impact Factor. A journal in Q1 performs better than at least 75% of the journals in that category on Impact Factor (Clarivate, n.d.-a).
  • Preparing for these journals: You search for studies in these indexes on Web of Science and upload the exported file to SRL Engine. Journals that endorse PRISMA may ask for the checklist and flow diagram (PRISMA, n.d.-a). The program prepares the flow diagram, the search strategy table, the inter-rater agreement sentence, the risk-of-bias figures and the certainty-of-evidence tables.
  • What the program does not do: It has no effect on a journal's decision. It does not set the research question, build the search strategy or interpret the findings for you.
  • Choosing a journal: The SCIE, SSCI, ESCI and journal quartile check guide shows how to confirm a journal's index and quartile from official sources, and the fast publication journals guide explains how to read time to first decision.

AI and credits

  • Steps that use AI: title and abstract screening, data extraction, quality appraisal, grouping values in an analysis field into categories, drafting the synthesis and writing report sections.
  • Before these operations start, a confirmation window shows how many credits they will use.
  • The EN/TR switch in the screening decision window uses AI to translate a study's title and abstract into Turkish. This translation also costs credits, and it starts without a confirmation window.
  • Finding duplicates, PRISMA counts, kappa and the other agreement measures, tool suggestions and figures cost no credits.
  • Screening decisions made by AI carry a robot icon. Plans and credit packages are on the pricing page.
  • AI screening and data extraction are covered in more detail on the AI for systematic reviews page.

Limits to know about

  • The PRISMA diagram uses the template for new reviews. There is no template for updated reviews.
  • Section headings in the full Word report are in Turkish.
  • RoB 2 and ROBINS-I have no signalling-question algorithm; you enter the domain judgements.
  • There is no dedicated workflow for rapid reviews or scoping reviews.
  • Bibliometric analysis is a separate module: see bibliometric analysis tool. If your review includes a meta-analysis, see meta-analysis software.

Getting started

  1. Create an account.
  2. Open a project in Reference Management, upload your database files and remove duplicates.
  3. Write your inclusion and exclusion criteria and screen titles and abstracts. Assign coders for independent coding if you need to.
  4. Send the included records to a new systematic review project with "Send to module".
  5. Work through planning, screening, extraction, quality, analysis and synthesis in order.
  6. On the Reporting tab, download the PRISMA diagram and the Word report.

Frequently asked questions

Will a systematic review get published in a Q1 or SSCI journal?

The journal's editors and reviewers decide; no software can guarantee acceptance. Journals that endorse PRISMA may ask for a completed PRISMA checklist and flow diagram at submission (PRISMA, n.d.-a). SRL Engine builds the flow diagram, the search strategy table, the inter-rater agreement sentence, the risk-of-bias figures and the APA 7 tables from your project records. The review question, the search and the interpretation are still your work.

Can a systematic review be a quick paper?

For 195 reviews registered in PROSPERO, the mean time from registration to publication was 67.3 weeks (Borah et al., 2017). SRL Engine cuts the mechanical work: finding duplicates, counting for PRISMA, computing kappa and building tables. Searching, screening decisions and quality judgements still take time. If time really is short, a rapid review is a separate method, and the Cochrane Rapid Reviews Methods Group has published 26 recommendations for it (Garritty et al., 2021). The software has no dedicated rapid review workflow.

How many people should screen?

The Cochrane Handbook asks for at least two people working independently to decide whether each study meets the eligibility criteria, and treats this as essential for the final decision based on full texts (Lefebvre et al., 2025). In SRL Engine the project owner or an administrator assigns the same records to two or more coders, who work on the independent coding screen without seeing each other's decisions.

Does the AI make the screening decisions?

AI screening writes an include, exclude or uncertain decision for each record based on your inclusion and exclusion criteria. These decisions carry a robot icon and are stored with their reasoning, and you can change any of them. AI screening costs credits. Inter-rater agreement is calculated only from the decisions two people enter on the independent coding screen.

References

Borah, R., Brown, A. W., Capers, P. L., & Kaiser, K. A. (2017). Analysis of the time and workers needed to conduct systematic reviews of medical interventions using data from the PROSPERO registry. BMJ Open, 7(2), Article e012545. https://doi.org/10.1136/bmjopen-2016-012545

Byrt, T., Bishop, J., & Carlin, J. B. (1993). Bias, prevalence and kappa. Journal of Clinical Epidemiology, 46(5), 423–429. https://doi.org/10.1016/0895-4356(93)90018-V

Campbell, M., McKenzie, J. E., Sowden, A., Katikireddi, S. V., Brennan, S. E., Ellis, S., Hartmann-Boyce, J., Ryan, R., Shepperd, S., Thomas, J., Welch, V., & Thomson, H. (2020). Synthesis without meta-analysis (SWiM) in systematic reviews: Reporting guideline. BMJ, 368, Article l6890. https://doi.org/10.1136/bmj.l6890

Clarivate. (n.d.-a). Journal Citation Reports: Learn the basics. Clarivate LibGuides. Retrieved November 21, 2026, from https://clarivate.libguides.com/jcr

Clarivate. (n.d.-b). Science Citation Index Expanded. Retrieved November 21, 2026, from https://clarivate.com/academia-government/scientific-and-academic-research/research-discovery-and-referencing/web-of-science/web-of-science-core-collection/science-citation-index-expanded/

Clarivate. (n.d.-c). Social Sciences Citation Index. Retrieved November 21, 2026, from https://clarivate.com/academia-government/scientific-and-academic-research/research-discovery-and-referencing/web-of-science/web-of-science-core-collection/social-sciences-citation-index/

Clarivate. (2026, November 13). Web of Science Core Collection - Turkish [In Turkish]. Clarivate LibGuides. https://clarivate.libguides.com/mena/tr/WoSCore

Cohen, J. (1960). A coefficient of agreement for nominal scales. Educational and Psychological Measurement, 20(1), 37–46. https://doi.org/10.1177/001316446002000104

Garritty, C., Gartlehner, G., Nussbaumer-Streit, B., King, V. J., Hamel, C., Kamel, C., Affengruber, L., & Stevens, A. (2021). Cochrane Rapid Reviews Methods Group offers evidence-informed guidance to conduct rapid reviews. Journal of Clinical Epidemiology, 130, 13–22. https://doi.org/10.1016/j.jclinepi.2020.10.007

Guyatt, G., Oxman, A. D., Akl, E. A., Kunz, R., Vist, G., Brozek, J., Norris, S., Falck-Ytter, Y., Glasziou, P., & deBeer, H. (2011). GRADE guidelines: 1. Introduction—GRADE evidence profiles and summary of findings tables. Journal of Clinical Epidemiology, 64(4), 383–394. https://doi.org/10.1016/j.jclinepi.2010.04.026

Higgins, J. P. T., Savović, J., Page, M. J., Elbers, R. G., & Sterne, J. A. C. (2024). Chapter 8: Assessing risk of bias in a randomized trial. In J. P. T. Higgins, J. Thomas, J. Chandler, M. Cumpston, T. Li, M. J. Page, & V. A. Welch (Eds.), Cochrane handbook for systematic reviews of interventions (Version 6.5). Cochrane. https://www.cochrane.org/authors/handbooks-and-manuals/handbook/current/chapter-08

Hong, Q. N., Fàbregues, S., Bartlett, G., Boardman, F., Cargo, M., Dagenais, P., Gagnon, M.-P., Griffiths, F., Nicolau, B., O'Cathain, A., Rousseau, M.-C., Vedel, I., & Pluye, P. (2018). The Mixed Methods Appraisal Tool (MMAT) version 2018 for information professionals and researchers. Education for Information, 34(4), 285–291. https://doi.org/10.3233/EFI-180221

Landis, J. R., & Koch, G. G. (1977). The measurement of observer agreement for categorical data. Biometrics, 33(1), 159–174. https://doi.org/10.2307/2529310

Lefebvre, C., Glanville, J., Briscoe, S., Featherstone, R., Littlewood, A., Metzendorf, M.-I., Noel-Storr, A., Paynter, R., Rader, T., Thomas, J., & Wieland, L. S. (2025). Chapter 4: Searching for and selecting studies. In J. P. T. Higgins, J. Thomas, J. Chandler, M. Cumpston, T. Li, M. J. Page, & V. A. Welch (Eds.), Cochrane handbook for systematic reviews of interventions (Version 6.5.1). Cochrane. https://www.cochrane.org/authors/handbooks-and-manuals/handbook/current/chapter-04

Lewin, S., Booth, A., Glenton, C., Munthe-Kaas, H., Rashidian, A., Wainwright, M., Bohren, M. A., Tunçalp, Ö., Colvin, C. J., Garside, R., Carlsen, B., Langlois, E. V., & Noyes, J. (2018). Applying GRADE-CERQual to qualitative evidence synthesis findings: Introduction to the series. Implementation Science, 13(Suppl. 1), Article 2. https://doi.org/10.1186/s13012-017-0688-3

Page, M. J., McKenzie, J. E., Bossuyt, P. M., Boutron, I., Hoffmann, T. C., Mulrow, C. D., Shamseer, L., Tetzlaff, J. M., Akl, E. A., Brennan, S. E., Chou, R., Glanville, J., Grimshaw, J. M., Hróbjartsson, A., Lalu, M. M., Li, T., Loder, E. W., Mayo-Wilson, E., McDonald, S., … Moher, D. (2021). The PRISMA 2020 statement: An updated guideline for reporting systematic reviews. BMJ, 372, Article n71. https://doi.org/10.1136/bmj.n71

PRISMA. (n.d.-a). Endorsement. Retrieved November 21, 2026, from https://www.prisma-statement.org/endorsement

PRISMA. (n.d.-b). PRISMA 2020 flow diagram. Retrieved November 21, 2026, from https://www.prisma-statement.org/prisma-2020-flow-diagram

Sterne, J. A. C., Hernán, M. A., Reeves, B. C., Savović, J., Berkman, N. D., Viswanathan, M., Henry, D., Altman, D. G., Ansari, M. T., Boutron, I., Carpenter, J. R., Chan, A.-W., Churchill, R., Deeks, J. J., Hróbjartsson, A., Kirkham, J., Jüni, P., Loke, Y. K., Pigott, T. D., … Higgins, J. P. T. (2016). ROBINS-I: A tool for assessing risk of bias in non-randomised studies of interventions. BMJ, 355, Article i4919. https://doi.org/10.1136/bmj.i4919

Sterne, J. A. C., Savović, J., Page, M. J., Elbers, R. G., Blencowe, N. S., Boutron, I., Cates, C. J., Cheng, H.-Y., Corbett, M. S., Eldridge, S. M., Emberson, J. R., Hernán, M. A., Hopewell, S., Hróbjartsson, A., Junqueira, D. R., Jüni, P., Kirkham, J. J., Lasserson, T., Li, T., … Higgins, J. P. T. (2019). RoB 2: A revised tool for assessing risk of bias in randomised trials. BMJ, 366, Article l4898. https://doi.org/10.1136/bmj.l4898

Waffenschmidt, S., Knelangen, M., Sieben, W., Bühn, S., & Pieper, D. (2019). Single screening versus conventional double screening for study selection in systematic reviews: A methodological systematic review. BMC Medical Research Methodology, 19(1), Article 132. https://doi.org/10.1186/s12874-019-0782-0