SRL Engine

AI for Systematic Reviews and Meta-Analysis: Screening and Data Extraction

Author: Hamza Polat · ORCID 0000-0002-9646-7507

Published:

In SRL Engine, AI helps with two tasks in a systematic review or meta-analysis: title/abstract screening and data extraction from full texts. Every screening decision shows its reason, and every extracted value shows the sentence it was taken from in the paper. AI decisions are marked separately, so you can change, delete or rerun any of them. Every step that uses AI costs credits, and the cost is on screen before the step starts.

SRL Engine does not search databases for you. You run your search in Web of Science, Scopus or PubMed and import the results as a BibTeX, RIS, PubMed or CSV/Excel file. The AI then works on those records and on the studies' PDFs.

What the AI does and what stays with you

StepThe AIYouCredits charged
Title/abstract screening (Reference Management)Labels each record Included, Excluded or Uncertain; writes the reason and, if any, the criterion it rests onWrite the criteria, then review and change the decisionsPer run
Data extraction (Systematic Review)Fills the fields you define from the full text and attaches a source sentence to each valueDefine the fields, compare each value with its source and correct itPer study
Data extraction (Meta-Analysis)Pulls the numbers needed for the effect size out of the PDF, with their source sentenceCheck the rows and verify them where neededPer study or per PDF
Verification (Meta-Analysis)Compares a row with its article and proposes corrections or missing rowsSave the proposal or leave itFirst analysis and each further message

AI also helps with quality appraisal, synthesis of findings and report sections. Those features are described on the systematic review software and meta-analysis software pages.

Title and abstract screening

Screening happens in the Screening (Include/Exclude) window of the Reference Management module. First you write your inclusion and exclusion criteria. AI screening will not start until there is at least one inclusion criterion.

The AI Auto Screening button reads the records that do not have a decision yet. The AI sees the title, abstract, keywords and record details such as year, journal, document type and language; it does not read the full text. For each record it writes one of three decisions: Included, Excluded or Uncertain. Next to the decision you see the reason, the criterion it rests on (if any) and a confidence percentage. The confidence percentage is a number the model gives in its own answer; do not read it as a calculated probability.

The rules given to the AI make exclusion harder than inclusion:

  • To exclude a record because of its content, the AI has to quote the words in the title or abstract that support the exclusion. If it cannot quote them, it may not exclude.
  • An abstract that says nothing about a criterion is not a reason to exclude. Such a record is included, and the person who reads the full text checks the criterion.
  • If a record clearly names a different population, intervention or design from the one the review asks for, that inclusion criterion counts as not met and the record can be excluded.
  • Uncertain is used when it is not clear what the record is about, or when the record contradicts itself on a criterion that decides the outcome.

The reasoning is simple: a record included by mistake costs one full-text check, while a record excluded by mistake drops silently out of the review. These are instructions to the model, not guarantees. You still need to review the exclusions.

The final decision is yours:

  • An AI decision is applied to the record straight away and stays in place until you change it. Review the decisions before you send the records to another project.
  • AI decisions are marked with a robot icon in the list.
  • You can change any decision in the list or in the decision window. The window shows the latest decision on the record (the AI's or yours) together with its reason.
  • The Re-screen Uncertain button rescreens only the records that are still uncertain.
  • Clear AI Decisions Only deletes the AI decisions and leaves your own decisions untouched.
  • You can have a second person code the same records independently and measure the agreement between the two of you (Cohen's kappa). The inter-rater reliability guide explains how to read the result.

You then send the screened records to a systematic review, meta-analysis or bibliometric project. Systematic review and meta-analysis projects also receive the excluded records with their reasons, and the exclusion reasons in the PRISMA 2020 flow diagram are filled in from them.

AI screening is charged per run, whatever the number of records. Rescreening the uncertain records is a new run. Deciding by hand uses no credits.

Data extraction from full texts

In the Data Extraction stage of the Systematic Review module, you first define your extraction fields, such as sample size, country, measurement instrument or main finding. Extraction fields are filled as text; coding the values as numbers, yes/no or categories happens later, in the Analysis stage. If you add a description to a field, the AI reads it too. You can also start from the 25-field standard template. Its bibliographic fields (title, authors, year, journal, DOI) are filled from the record itself, not by the AI.

The AI reads the study's PDF text, and tables are kept and read separately. For a study without a PDF, only the title and abstract are read. A scanned PDF made only of images has no text layer, so the AI cannot read it.

The source of every value is checked:

  • For each value, the AI is asked to give a verbatim sentence or short passage from the paper.
  • The software searches the study text for that quote, or for the value itself if no quote was given. If it cannot find it, the value is not saved and the field stays "Not reported".
  • Fields left empty get a second, more focused read. A value found there goes through the same check.
  • In the form, an icon appears next to every field that has a source; hover over it to see the source sentence. In the study's detail window, clicking a field name highlights that sentence in yellow in the PDF and scrolls the page to it.

If you add new fields later, the "Fill missing fields only" option sends only the empty fields of already extracted studies to the AI. Filled cells, including the ones you corrected by hand, are left alone.

Bulk extraction is charged per study. Studies that are already extracted, excluded, marked as duplicates or have no text to read are skipped. The number skipped is shown, and no credits are charged for them.

Data extraction and verification for meta-analysis

On the PDF Extraction tab of the Meta-Analysis module, the AI pulls the numbers needed to calculate the effect size out of each included article. For continuous outcomes these are the group means, standard deviations and sample sizes; for binary outcomes, the event counts and group totals. Each row comes with the sentence or table cell the numbers were read from.

  • If a row's quote cannot be found in the PDF text, a red warning icon appears next to the row and asks you to check the values against the article. The numbers are not deleted.
  • In extraction fields you define yourself (for example, country or length of the intervention), a value whose quote cannot be found in the article is not saved.
  • The source viewer counts how many quotes were found in the PDF and how many were not.
  • When you have finished checking a study, you can mark it as "Checked".

Every row in the Data table has a Verify button. It opens the article's PDF on one side and a chat on the other. The AI compares the row's numbers with the article, lists the values that match, and where needed proposes corrections or rows that are in the article but missing from your table. You can also ask questions in the chat, for example "Why is the post-test mean in Table 2 72.4?".

  • Nothing is written to your data until you save. The AI never changes or deletes a row on its own.
  • There is no bulk verification; rows are verified one at a time.
  • Verification needs a topic title or a Web of Science query in the project settings.
  • Verification is charged for the first analysis and for each further message. Once you have had one row of an article analysed, the first analysis of the other rows from the same article costs no extra credits.

For the correlation and proportion modules, the accuracy of AI data extraction was measured on a separate test set built from open-access articles. The share of rows found, the accuracy of the values and whether any value absent from the text was written are published on the Validation page. Screening and the other modules were not part of this measurement.

Credits

  • Before a step that uses AI starts, a confirmation dialog opens. It shows how many credits the step will use and how many you have left. In verification, the dialog opens once, before your first message, and also states the cost of each further message.
  • If you do not have enough credits, the step does not start.
  • If you use a stronger AI tier (Pro or Ultra), the same step uses more credits, and the dialog shows the multiplier.
  • The monthly credits of each plan are listed in the Plans section. Current per-step costs are in the "AI Standard Credit Costs" section of the Plans and Pricing page once you sign in.
  • Used credits are not refunded (Cancellation and Refund Terms).
  • Deciding by hand and entering or correcting values by hand use no credits.

Limits and responsibility

Published results on how well large language models (LLMs) perform in systematic reviews are mixed:

  • A scoping review of 37 studies in health research found that LLMs had been tried in 10 of the 13 steps of a systematic review. About half of the studies judged the results promising, a quarter neutral and a fifth not promising. The authors note that fully established or validated applications are often lacking (Lieberum et al., 2025).
  • In a pre-registered study that tested GPT-4 with no human in the loop, data extraction performance was only moderate once chance agreement and dataset imbalance were accounted for. Screening performance ranged from none to moderate depending on the dataset. In full-text screening with highly reliable prompts, it reached human-like levels. Even so, the authors advise substantial caution (Khraisha et al., 2024).
  • In a proof-of-concept study, a language model (Claude 2) extracted 160 data elements from 10 randomised controlled trials with 96.3% accuracy. Four of its six errors were missed data items (Gartlehner et al., 2024).

These studies do not measure SRL Engine. They show why AI output has to be checked. The checks in SRL Engine have limits too:

  • The source-sentence check looks for the quote in the article text; for a long quote, finding one part of it in the text is enough. It does not confirm that the value was taken from the right row or cell.
  • The screening rules are instructions to the model; wrong include or exclude decisions can still happen.
  • Content you send during AI steps may be passed to third-party AI providers (Terms of Service).

State your use of AI clearly in your report. Items 8 and 9 of PRISMA 2020 ask for details of any automation tools used in the selection and data collection processes (Page et al., 2021). The 2025 joint position statement of Cochrane, the Campbell Collaboration, JBI and the Collaboration for Environmental Evidence (CEE) asks authors to declare any AI use that makes or suggests judgements, such as on study eligibility or data extraction (Flemyng et al., 2025). The YÖK guide in Turkey also asks you to state the tool's name, when it was used, at which stage and its version (Yükseköğretim Kurulu, 2024). An example sentence:

The AI screening feature of SRL Engine was used for title and abstract screening ([date]). All AI decisions were reviewed by [number] researchers, and disagreements were resolved by discussion.

How to get started

  1. Create an account and start a new project in Reference Management.
  2. Import the record files you exported from the databases.
  3. In the Screening (Include/Exclude) window, write your inclusion and exclusion criteria and start AI Auto Screening. Review the decisions.
  4. Send the included records to a systematic review or meta-analysis project and attach their PDFs.
  5. In a systematic review, define your extraction fields and start bulk extraction; in a meta-analysis, use the PDF Extraction tab. Compare every value with its source sentence.

Frequently asked questions

Can AI make screening decisions on its own?

In SRL Engine the AI writes a decision and a reason for every record. The decision is applied to the record straight away, but it is marked with a robot icon and you can change any of them, so review the decisions before you send the records on. The 2025 joint position statement of Cochrane, the Campbell Collaboration, JBI and the Collaboration for Environmental Evidence (CEE) also asks for AI to be used with human oversight and leaves responsibility for the review with its authors (Flemyng et al., 2025).

Can I use AI for the literature review in my thesis?

Check your university's and graduate school's rules first. In Turkey, the 2024 ethics guide of the Council of Higher Education (YÖK) says generative AI may be used in literature reviews, and asks you to keep in mind the risks of fabricated references, missed recent sources and bias. It also says you should state which tool you used, when, at which stage of the study and in which version, and that the accuracy of the content is the user's responsibility.

Can the AI make up a value that is not in the paper?

To guard against this, the source quote of every value is searched for in the article text. In a systematic review project, a value whose quote cannot be found is not saved. In a meta-analysis project, the row is flagged with a warning icon. The check confirms that the quote appears in the text; it does not confirm that the value came from the right cell. Comparing each value with its source is still up to you.

Can data be extracted from scanned PDFs?

No. The AI reads the PDF's text layer, and a scanned PDF made only of images has no text to read. You can enter the data for those studies by hand.

How many credits do AI steps use?

The cost is shown in a confirmation dialog, together with your remaining credits, before the step starts; if you do not have enough credits, it does not start. Screening is charged per run, bulk data extraction per study or per PDF, and verification for the first analysis and each further message. Screening by hand and entering data by hand use no credits. Used credits are not refunded.

References

Flemyng, E., Noel-Storr, A., Macura, B., Gartlehner, G., Thomas, J., Meerpohl, J. J., Jordan, Z., Minx, J., Eisele-Metzger, A., Hamel, C., Jemioło, P., Porritt, K., & Grainger, M. (2025). Position statement on artificial intelligence (AI) use in evidence synthesis across Cochrane, the Campbell Collaboration, JBI, and the Collaboration for Environmental Evidence 2025. JBI Evidence Synthesis, 23(11), 2162–2166. https://doi.org/10.11124/JBIES-25-00480

Gartlehner, G., Kahwati, L., Hilscher, R., Thomas, I., Kugley, S., Crotty, K., Viswanathan, M., Nussbaumer-Streit, B., Booth, G., Erskine, N., Konet, A., & Chew, R. (2024). Data extraction for evidence synthesis using a large language model: A proof-of-concept study. Research Synthesis Methods, 15(4), 576–589. https://doi.org/10.1002/jrsm.1710

Khraisha, Q., Put, S., Kappenberg, J., Warraitch, A., & Hadfield, K. (2024). Can large language models replace humans in systematic reviews? Evaluating GPT-4's efficacy in screening and extracting data from peer-reviewed and grey literature in multiple languages. Research Synthesis Methods, 15(4), 616–626. https://doi.org/10.1002/jrsm.1715

Lieberum, J.-L., Toews, M., Metzendorf, M.-I., Heilmeyer, F., Siemens, W., Haverkamp, C., Böhringer, D., Meerpohl, J. J., & Eisele-Metzger, A. (2025). Large language models for conducting systematic reviews: On the rise, but not yet ready for use—A scoping review. Journal of Clinical Epidemiology, 181, Article 111746. https://doi.org/10.1016/j.jclinepi.2025.111746

Page, M. J., McKenzie, J. E., Bossuyt, P. M., Boutron, I., Hoffmann, T. C., Mulrow, C. D., Shamseer, L., Tetzlaff, J. M., Akl, E. A., Brennan, S. E., Chou, R., Glanville, J., Grimshaw, J. M., Hróbjartsson, A., Lalu, M. M., Li, T., Loder, E. W., Mayo-Wilson, E., McDonald, S., … Moher, D. (2021). The PRISMA 2020 statement: An updated guideline for reporting systematic reviews. BMJ, 372, Article n71. https://doi.org/10.1136/bmj.n71

Yükseköğretim Kurulu. (2024). Yükseköğretim kurumları bilimsel araştırma ve yayın faaliyetlerinde üretken yapay zekâ kullanımına dair etik rehber [Ethics guide on the use of generative artificial intelligence in the scientific research and publication activities of higher education institutions]. https://proje.yok.gov.tr/documentFiles/17539645334.Y%C3%BCksek%C3%B6%C4%9Fretimde%20%C3%BCretken%20yapay%20zeka%20kullan%C4%B1m%C4%B1-tr.pdf