SRL Engine

How to Assess Publication Bias: Funnel Plot, Egger's Test and Trim-and-Fill

Author: Nurullah Taş · ORCID 0000-0002-8312-8733

Published:

Publication bias arises when the direction or statistical significance of a study's result affects whether it gets published. Statistically significant results are easier to find, so a meta-analysis built only on published studies can overstate the effect (Page et al., 2024). Three tools are used to look for it. The funnel plot is a visual check. Egger's regression test puts a number on the plot's asymmetry. Trim-and-fill estimates what the result would be if the missing studies were added. All three ask the same question: do small studies give different results from large ones? If a meta-analysis has fewer than 10 studies, asymmetry tests should not be used, because with so few studies their power is low (Page et al., 2024).

What is publication bias?

The Cochrane Handbook treats the problem under a broader name, non-reporting bias. It arises when decisions about how, when or where to report a study's results are influenced by the P value, or by the size or direction of the effect. Significant results suggesting that an intervention works are more likely than non-significant ones to be available, to be available quickly, to appear in high-impact journals and to be cited. That makes them easier for a systematic review to find (Page et al., 2024).

Sterne and colleagues (2011) group reporting biases into three kinds: publication bias, selective outcome reporting and selective analysis reporting. Delayed publication, language bias and citation bias are forms of publication bias.

How much can it change a result? In an example the Handbook describes, Eyding and colleagues asked the manufacturer for data on trials comparing reboxetine with placebo for depression. Across the 13 trials identified, data for only 26% had been published. A meta-analysis of the two published trials showed a negligible difference in withdrawals due to adverse events. When six unpublished trials were added, patients on reboxetine were more than twice as likely to withdraw (Eyding et al., 2010, as cited in Page et al., 2024).

How to read a funnel plot

A funnel plot draws each study as a point. The effect size runs along the horizontal axis and the standard error (SE) up the vertical axis. Cochrane recommends the standard error rather than the total sample size on the vertical axis. Plotted on a reversed scale, it puts the larger, more precise studies at the top (Page et al., 2024). Estimates from small studies scatter widely at the bottom, and the spread narrows towards the top. Without bias and heterogeneity, the points form a symmetrical inverted funnel (Sterne et al., 2011).

The plot can also include a triangle that extends 1.96 standard errors either side of the pooled effect. Without bias and heterogeneity, about 95% of studies should fall inside it (Page et al., 2024). In Cochrane's description the triangle is centred on the fixed-effect estimate. The figure below, like SRL Engine, centres it on the pooled effect of the main analysis.

Funnel plot of the seven-study example. Hedges' g runs along the horizontal axis and the standard error, reversed, up the vertical axis. A blue dashed vertical line marks the pooled effect (g = 0.38), a grey dashed triangle marks the ±1.96 SE limits, and a red dashed line marks zero. Study B lies just outside the triangle on the left and study G outside it on the right.

Figure 1. Funnel plot of the seven studies from the forest plot guide (the studies are not real). Effect measure Hedges' g; the vertical line is the pooled effect from the random-effects model. Drawn for this guide with the same plotting rules as the SRL Engine funnel plot.

What the example shows

The data are the seven studies from the forest plot guide. The pooled effect is g = 0.38, 95% CI [0.06, 0.71], and heterogeneity is I² = 58.7%.

  • The largest study, B (238 participants, SE = 0.13), sits at the top. It lies to the left of the pooled effect, just outside the limit.
  • Study G (SE = 0.25) lies outside the right-hand limit.
  • Two of the smaller studies, F and G, are on the right and report large effects. But the smallest study, A, is on the left with a negative effect.

Two studies outside the limits look more like extra horizontal spread than asymmetry. If the heterogeneity fits the assumptions of the random-effects model, the funnel stays symmetrical but with additional horizontal scatter (Sterne et al., 2011). Seven points are too few for the eye to decide. As the next sections show, the tests do not tell you much with so few studies either.

Asymmetry does not always mean bias

An asymmetrical funnel shows that small studies give different results from large ones. This is called a small-study effect. Cochrane treats the funnel plot as a general way of displaying small-study effects. Asymmetry on its own does not diagnose non-reporting bias (Page et al., 2024). Possible causes:

CauseHow it creates asymmetry
Reporting biasesSmall studies with non-significant results go unpublished, or their results are reported incompletely.
Methodological problems in small studiesPoor design or inadequate analysis inflates the effects of smaller studies.
Genuine heterogeneityThe effect depends on study size. For example, high-risk participants end up mainly in small early studies, or the intervention is delivered less thoroughly in large studies.
ArtefactSome effect measures are mathematically linked to their standard errors.
ChanceAsymmetry can also occur by chance.

Sources: Sterne et al. (2011), Box 1; Page et al. (2024), Table 13.3.b.

A contour-enhanced funnel plot helps to tell these causes apart. It adds lines for conventional significance levels such as p < .01, .05 and .10. If the apparently missing studies fall in the non-significant area, publication bias becomes a more credible explanation. If they fall in the significant area, the asymmetry is more likely to have another cause, such as study quality (Peters et al., 2008).

Egger's test

Egger and colleagues (1997) measured asymmetry with a regression. Each study's standard normal deviate (effect / SE) is regressed on its precision (1 / SE). With no small-study effect, the regression line passes through the origin and the intercept is close to zero. The further the intercept is from zero, the greater the asymmetry. A positive intercept means that smaller studies report larger effects. The same test can be set up as a weighted linear regression of the effect estimates on their standard errors (Sterne et al., 2011).

Egger and colleagues applied the test to published meta-analyses. Asymmetry indicated bias in 38% of meta-analyses from four leading general medical journals (14 of 37) and in 13% of Cochrane reviews (5 of 38) (Egger et al., 1997).

Limits of the test

  • Low power. Asymmetry tests usually have low power. Even when a test finds no evidence of asymmetry, bias cannot be ruled out (Sterne et al., 2011).
  • The 10-study rule. Cochrane advises using asymmetry tests only when the meta-analysis includes at least 10 studies (Page et al., 2024). With substantial heterogeneity the minimum may be well above 10 (Sterne et al., 2011).
  • Studies of similar size. If the standard errors are all similar, that is, the studies are of similar size, the test should not be used (Page et al., 2024).
  • Artefacts of the effect measure. For odds ratios (OR) and standardized mean differences (SMD), the effect size is artefactually correlated with its standard error. Cochrane does not recommend the original Egger test for these measures and points to the tests of Harbord and of Peters for odds ratios (Page et al., 2024). For SMDs, conventional asymmetry tests have inflated Type I error. A simple modification to the standard error formula, or a variance-stabilizing transformation, keeps the error rate close to its nominal level (Pustejovsky & Rodgers, 2019).
  • A strategy set in advance. Decide on the test in advance where possible. If you use more than one test, report all of the results (Sterne et al., 2011).

Egger's test in the example

The example has seven studies, so by the rule the test would not be reported. The results are shown here only to illustrate how to read them:

StatisticValue
Intercept (b₀)2.10
Standard error of the intercept1.95
t (df = 5)1.08
p.33
95% CI of the intercept−2.90 to 7.11

The intercept is positive: the smaller studies lean towards larger effects. But the confidence interval is very wide and includes zero. This result cannot be read as "no publication bias". With seven studies, the test would most likely miss a real asymmetry. And because Hedges' g is an SMD, the artefact warning above applies as well.

Begg and Mazumdar's (1994) rank correlation test is not significant either, Kendall's τ = 0.14. This test has only moderate power even in meta-analyses of 25 studies. A non-significant result does not rule out bias (Begg & Mazumdar, 1994).

Trim-and-fill

Trim-and-fill is a rank-based data augmentation method proposed by Duval and Tweedie (2000). It formalizes the logic of the funnel plot. It estimates how many studies might be missing (k₀) and how they would have changed the result. The steps are:

  1. The most extreme small studies on the asymmetric side are set aside (trim).
  2. The centre is re-estimated from the remaining studies, and k₀ is recalculated around the new centre. The first two steps repeat until k₀ stops changing.
  3. The trimmed studies are put back, and the mirror image of each one around the centre is added on the opposite side (fill).
  4. The pooled effect is recalculated with the filled studies.

In the authors' simulations, the point estimate after filling was approximately correct and the coverage of the confidence intervals improved substantially (Duval & Tweedie, 2000). Later simulations showed a different picture when studies are heterogeneous:

  • With heterogeneous studies, trim-and-fill may adjust for publication bias where none exists. Terrin and colleagues (2003) concluded that the funnel plot itself is inappropriate for heterogeneous meta-analyses.
  • With large between-study heterogeneity and no publication bias, the method can underestimate a true positive effect. Because we cannot know whether funnel plot asymmetry is really caused by publication bias, Peters and colleagues (2007) recommend using trim-and-fill as a sensitivity analysis, as its authors intended.

So the adjusted estimate does not replace the main result. Report it next to the main result, as an answer to the question "how much would the result change if studies were missing?"

In the example, trim-and-fill estimated no missing studies (k₀ = 0), and the pooled effect stayed at g = 0.38. That does not prove the absence of bias either. A funnel made of seven points is a weak basis for the method, and the data show marked heterogeneity (I² = 58.7%). The heterogeneity guide explains how to interpret it.

What to do with fewer than 10 studies

Below 10 studies, instead of asymmetry tests and trim-and-fill, you can:

  • Present the funnel plot with caution. When a meta-analysis rests on a few small trials, its capacity to detect bias is limited, and results should be treated with considerable caution (Egger et al., 1997).
  • State that the tests were not run, and why. A sentence such as "With seven studies, tests for funnel plot asymmetry were not performed" is enough.
  • Look beyond the published literature. Trial registers and manufacturer data can lead to unpublished results; the reboxetine example shows why this matters (Page et al., 2024).
  • Compare planned and reported outcomes. Suspicion is raised when results are missing for an outcome pre-specified in a register or protocol (Page et al., 2024).
  • Use a structured tool. Cochrane's ROB-ME (Risk Of Bias due to Missing Evidence) tool is the first structured approach for assessing the risk of bias due to missing evidence (Page et al., 2024).

How to report it

Two PRISMA 2020 items cover this. Item 14, in the Methods, asks how the risk of bias due to missing results (arising from reporting biases) was assessed. Item 21, in the Results, asks for that assessment for each synthesis (Page et al., 2021).

Example for the Methods section:

Small-study effects were examined with a funnel plot. Egger's regression test was applied only to analyses with at least 10 studies (Page et al., 2024). Trim-and-fill (L0 estimator) was reported as a sensitivity analysis.

Example Results sentence for the example data:

With seven studies, tests for funnel plot asymmetry were not performed, because below ten studies these tests have low power (Sterne et al., 2011). The funnel plot is shown in Figure [n]. Two studies fell outside the pseudo 95% limits, which is consistent with the observed heterogeneity (I² = 58.7%).

With 10 or more studies, a test result could be written like this (fill in your own values in the brackets):

Egger's test showed no significant funnel plot asymmetry, b₀ = [value], 95% CI [lower, upper], t([k − 2]) = [value], p = [value]. Because the test has limited power, publication bias cannot be ruled out.

Publication bias in SRL Engine

In SRL Engine's meta-analysis module, the Publication Bias tab brings these together:

  • Funnel plot. The vertical axis can show the reversed standard error or precision (1/SE). The ±1.96 SE limits are drawn around the pooled effect of the main analysis. The plot downloads as a PNG.
  • Egger's regression test and Begg's rank correlation test.
  • Trim-and-fill (L0 estimator). Filled studies appear on the plot in a separate colour.
  • Rosenthal's and Orwin's fail-safe N.

The on-screen guidance reminds you that with fewer than 10 studies the tests have low power. When there are fewer than 10 independent studies, the Word report leaves out the tests and the funnel plot and states instead that publication bias was not tested, citing Sterne et al. (2011). If a study contributes more than one effect size, the program flags it. If a dependence method is selected for the project, the tests run on data combined at the study level; if not, Egger's test is computed in a cluster-robust form (CHE + CR2). Trim-and-fill results always appear on screen. They go into the Word report only when the "Show trim-and-fill" switch in the project settings is on, and it is off by default.

The calculations were compared with the metafor package in R (Viechtbauer, 2010). In the measurement of 9 November 2026, 68 Egger's test values and 197 trim-and-fill values across 17 data sets were all within tolerance. The details are on the Validation page. The example numbers in this guide were computed both with SRL Engine's own calculation functions and with metafor 4.8-0, and the Egger and trim-and-fill results were the same.

The funnel plot and the tests do not use AI and do not cost credits. Having AI write report sections does cost credits. The meta-analysis software page describes everything the module does. To try it with your own data, create an account.

Frequently asked questions

How many studies do you need for Egger's test?

The Cochrane Handbook says at least 10 studies in the meta-analysis. With fewer, the test has low power. Sterne and colleagues (2011) add that with substantial heterogeneity the minimum may be well above 10. A non-significant test does not rule out publication bias.

Does a significant Egger's test mean there is publication bias?

No. A significant test shows that small studies give different results from large ones (a small-study effect). Publication bias is one possible cause. Poor methods in small studies, genuine heterogeneity, an artefactual link between the effect measure and its standard error, or chance can produce the same picture.

Can the trim-and-fill adjusted estimate be reported as the main result?

It is not recommended. When studies are heterogeneous the method can adjust for bias that does not exist. Peters and colleagues (2007) recommend using trim-and-fill as a sensitivity analysis, as its authors intended. Report it alongside the main result to show how much the estimate might change if studies were missing.

What should go on the vertical axis of a funnel plot?

Cochrane recommends plotting effect estimates against their standard error rather than the total sample size. With the standard error on a reversed scale, the larger, more precise studies sit at the top.

Where does publication bias go in a PRISMA 2020 report?

Item 14 in the Methods asks how the risk of bias due to missing results was assessed. Item 21 in the Results asks for that assessment for each synthesis.

References

Begg, C. B., & Mazumdar, M. (1994). Operating characteristics of a rank correlation test for publication bias. Biometrics, 50(4), 1088–1101. https://doi.org/10.2307/2533446

Duval, S., & Tweedie, R. (2000). Trim and fill: A simple funnel-plot-based method of testing and adjusting for publication bias in meta-analysis. Biometrics, 56(2), 455–463. https://doi.org/10.1111/j.0006-341X.2000.00455.x

Egger, M., Davey Smith, G., Schneider, M., & Minder, C. (1997). Bias in meta-analysis detected by a simple, graphical test. BMJ, 315(7109), 629–634. https://doi.org/10.1136/bmj.315.7109.629

Page, M. J., Higgins, J. P. T., & Sterne, J. A. C. (2024). Chapter 13: Assessing risk of bias due to missing evidence in a meta-analysis (last updated August 2024). In J. P. T. Higgins, J. Thomas, J. Chandler, M. Cumpston, T. Li, M. J. Page, & V. A. Welch (Eds.), Cochrane handbook for systematic reviews of interventions (Version 6.5). Cochrane. https://www.cochrane.org/authors/handbooks-and-manuals/handbook/current/chapter-13

Page, M. J., McKenzie, J. E., Bossuyt, P. M., Boutron, I., Hoffmann, T. C., Mulrow, C. D., Shamseer, L., Tetzlaff, J. M., Akl, E. A., Brennan, S. E., Chou, R., Glanville, J., Grimshaw, J. M., Hróbjartsson, A., Lalu, M. M., Li, T., Loder, E. W., Mayo-Wilson, E., McDonald, S., … Moher, D. (2021). The PRISMA 2020 statement: An updated guideline for reporting systematic reviews. BMJ, 372, Article n71. https://doi.org/10.1136/bmj.n71

Peters, J. L., Sutton, A. J., Jones, D. R., Abrams, K. R., & Rushton, L. (2007). Performance of the trim and fill method in the presence of publication bias and between-study heterogeneity. Statistics in Medicine, 26(25), 4544–4562. https://doi.org/10.1002/sim.2889

Peters, J. L., Sutton, A. J., Jones, D. R., Abrams, K. R., & Rushton, L. (2008). Contour-enhanced meta-analysis funnel plots help distinguish publication bias from other causes of asymmetry. Journal of Clinical Epidemiology, 61(10), 991–996. https://doi.org/10.1016/j.jclinepi.2007.11.010

Pustejovsky, J. E., & Rodgers, M. A. (2019). Testing for funnel plot asymmetry of standardized mean differences. Research Synthesis Methods, 10(1), 57–71. https://doi.org/10.1002/jrsm.1332

Sterne, J. A. C., Sutton, A. J., Ioannidis, J. P. A., Terrin, N., Jones, D. R., Lau, J., Carpenter, J., Rücker, G., Harbord, R. M., Schmid, C. H., Tetzlaff, J., Deeks, J. J., Peters, J., Macaskill, P., Schwarzer, G., Duval, S., Altman, D. G., Moher, D., & Higgins, J. P. T. (2011). Recommendations for examining and interpreting funnel plot asymmetry in meta-analyses of randomised controlled trials. BMJ, 343, Article d4002. https://doi.org/10.1136/bmj.d4002

Terrin, N., Schmid, C. H., Lau, J., & Olkin, I. (2003). Adjusting for publication bias in the presence of heterogeneity. Statistics in Medicine, 22(13), 2113–2126. https://doi.org/10.1002/sim.1461

Viechtbauer, W. (2010). Conducting meta-analyses in R with the metafor package. Journal of Statistical Software, 36(3), 1–48. https://doi.org/10.18637/jss.v036.i03